How Does A Fluxmeter Calculate Magnetic Flux?

Aug 20, 2022

Leave a message

How a fluxmeter calculates magnetic flux, a fluxmeter is a magnetic measuring instrument that measures magnetic flux. The fluxmeter measures the change in the magnetic field strength of the surface compared to the magnetic induction intensity b of the point measured by the Teslameter, ie, the magnetic flux φ = bs. The fluxmeter mainly consists of measuring coils and movable frame windings.


When the magnetic flux φ in the closed loop changes, the induced current flows through the frame windings, which causes the frame to have a certain degree of deflection α, Φ is proportional to α, and the magnetic flux (wb) is: Φ=(cα/n)×10 -3 c: Magnetic count shock coefficient, c = 1 (mwb); n: number of turns of the measurement coil; α: skewness.

There are three types of structures: magnetoelectric type, electronic type and digital integral type. At present, the mainstream digital integral structure is mainly used in China, combined with advanced analog electronic technology. It can use different types of test coils to measure the magnetic flux of the space magnetic field.

Fluxmeter is a professional magnetic measuring instrument. Based on a simple and practical design concept, we are committed to designing magnetic measurement products that are easy to operate and functional for users. The instrument has more practical peak lock and polarity judgment functions. The FLUXMETER Digital Fluxmeter is a precision magnetic measurement instrument designed and produced using low drift electronic integration devices. The response of this test is complete, and no data loss during the test is the best feature of this device. During the magnetic flux process of the sample tested by the pull method, fast and slow pull data can be kept consistent, repeated measurement and recovery test, especially excellent characteristics.

The FLUXMETER Digital Fluxmeter is a precision magnetic measurement instrument designed and produced using low-drift electronic integrating devices. The test response is complete, no data is lost during the test, high test accuracy and low drift are the main features of this instrument. During the magnetic flux process of the sample tested by the pull method, fast and slow pull data can be kept consistent, repeated measurement and recovery test, especially excellent characteristics.

The main functions are as follows:


●Test range: 2 gears, 20 gears, 200 gears, 2000 gears and four gears (can be changed as needed);

●Corresponding input impedance: 1k ohm, 10k ohm, 100k ohm, 1000k ohm;

●Power supply: AC 220V/0.5A;

●Test accuracy: 0.5%;

●Drift: 1uWb/min;

●Minimum resolution: 0.1uWb (equivalent to 2mwb range);

●Volume: 285mm×300mm×100mm, Weight: 3kg; (W*D*H);

●Working environment: 0℃ to +50℃, humidity: 35~80%;


Send Inquiry